Specifications For
Automatic Transfer Switches Arlington, VA
EMBASSEY
Remodel Nassau, Bahamas
EMBASSEY Mission
Residence Remodel Nassau, Bahamas
USIS BUILDING
Upgrades Mumbai, India
US CONSULATE
OFFICE - Electrical Up-Grade Bridgetown, Barbados
US CHANCERY -
Electrical
Up-Grade Copenhagen, Denmark
COB MUMBAI -
Replace
A/C Systems Mumbai,
India
USIS MUMBAI -
Replace Chiller
Plant Mumbai, India
USIS MUMBAI -
7th Floor
Apartment Mumbai, India
WASHINGTON HOUSE -
Emergency Generator Mumbai, India
U.S. EMBASSY - UPS
Up-Grade New Delhi, India
U.S. CONSULATE -
Consular Section Renovation Mumbai, India
U.S. CONSULATE -
Investigation Of Rear Property Wall Mumbai, India
U.S. CONSULATE -
Window Replacement Mumbai, India
CONSULATE Post
Generator And Ups System Upgrade Mumbai, India
- 2001 - Gerald R. Spencer, P.E. is the AE for the design of
the up-grade of the new Grounding, Uninterruptable Power System, and engine
generator for the secure communications systems, fuel supply and the secure
diesel fuel storage system for this site. Systems located in remote developing
countries will normally not get the maintenance needed for reliable back-up
power needed for diplomatic communications. This system added a 450KVA 50Hz
generator with a remote 8,000 gallon storage fuel tank. A fuel
transfer/distribution system was designed to supply the diesel fuel day-tank
inside the remote utility building. A secure fill detail was designed to prevent
fuel contamination by unauthorized personnel, and also allow fuel to be
delivered without the fuel truck entering the security fenced area of the
consulate property. Engine driven radiator fan will be configured to ventilate
the newly configured engine generator room. A 300KW auxiliary load bank will be
installed in the engine fan air discharge path in place of the radiator. Existing double doors on the north wall be removed and replaced with louvers for
engine driven fan air flow discharge. All other windows will be removed and
replaced with louvers for air intake. Radiator will be remotely mounted at the
roof level. Remote radiator will be purchased by the government to meet the DOS
criteria of 70DBA at 15' away from the radiator. Fuel piping and fuel
overflow/return piping will be double wall for secondary containment. A concrete
trench with a grating cover might allow for easier maintenance, but visitors
might trip, and the trench might not be visually appreciated. Overflow/return
piping is not trapped, but sloped to drain back into the underground fuel
storage tank. Secondary containment piping will slope with the fuel piping back
to the fuel tank to test wells/sumps where fluid indicating equipment can
monitor liquid leaks into the annular spaces. Electrical Power Company Voltage
drops of 20 % are normal, and not acceptable to the operation of the consulate.
The existing utility building was modified to have additional load carrying
capacity to carry the added engine generator loads. The existing building was
reinforced to resist seismic forces for Seismic Zone 3. The existing UPS system
was replaced with a system of greater capacity. We also designed a Forced Entry
rated/protected safe area with battery operated emergency ventilation and
emergency lighting for Consul officials security in times of civil unrest. We
also provided a new 75 KVA UPS system to serve the consulate communications and
minimum lighting. The Consulate Building was a historical landmark and the
modifications were made to minimize the visual impact to the facility.
|